... pardon me, but your split is showing ...




The Bad

If one peruses the plethora of Valve Phase Splitter circuit examples, almost none ever mention adjustment or distortion as if such circuits are perfectly balanced. This Google search of Constant Current Phase Splitter Schematics, which also includes many that are not CC.

Almost no schematics show and the accompanying text does not mention adjustment capability as if resistors and valves are all perfect devices. As this table shows, the greater the mismatch, the greater the Distortion which is the sum of the valve and the resistor mismatch.

ErrFormula
Δ: mismatch percent as decimal [0.00]
H: even harmonic number

DistTable

From the table above, it's clear that a slight resistor and valve gain mismatch creates significant distortion.

Waveform
Fundamental, Result and Distortion for ONE frequency.


EVERY frequency has similar distortion.


Notice that the distortion waveform is not a sine!


The simple answer would be to ensure a very close match in the plate resistors. However, it's not quite that simple as valves are imperfect devices varying orders of magnitude compared to solid state and sections vary within the same device can vary significantly.

Some amplifier manufacturers substitute switching devices for audio, e.g. 5963 for 12AU7. The switching devices may have a lower plate voltage and a larger performance delta between sections. These differences matter less in a gain stage for a channel than split between channels where they cause an level imbalance or a phase splitter where they will give rise to increased even harmonic distortion.

Measuring Phase Splitter Distortion

InstAmp
Since the phase splitter is two signals of opposite polarity, we needed a way to measure them summed and independent of the rest of the amplifier. Solution is a variable gain instrumentation amp.

InstAmp requires low noise ±15v supplies. Distortion lower than 0.002% of signal source. Input capable to 300+ VAC.

PCB, BOM & complete schematic available with a donation receipt to an animal welfare organization in your area.





Stock 2% Resistor Distortion

PSComp
With the stock 30k 2% resistors [29.95 and 29.65], five valves all measure around 0.50% THD.

The NOS GE 12AU7 is a reference valve and has near perfect Gm match between each triode.

The R7 & L7 relative levels should be a warning to valve rollers. These valves had all been on for more than 24 hours. Deltas are much different after only a few minutes. Swapping L7 & R7 results in more than 3/4dB level shift.


Optimizing the Phase Splitter

PSTrim
The simple phase splitter circuit modification at left allow almost perfect balance in the Phase Splitter. The stock anode resistors are reduced by about 10% and a pot about 20% of that reduced value are inserted. e.g. 30k * 90% -> 27k * 10% -> 5k pot.

If the distortion can't be lowered below 0.1% or voltage across the resistors can't be balanced, replace the valve! Note that distortion is somewhat level dependent. Setting with an input level ≈150mV for unbalanced kit should give good results.

Power dissipated in the pot is minimal. Bourns 3296 0.5w power rating is ample except in the case of a valve failure that sinks all the current through one triode and the pot is 0R on the other triode.



PSOptComp
Adding the trimmer above dropped the distortion by a factor of ten

The good news is that you don't need a lab full of gear to accomplish. A voltmeter or two, an insulated tweaker, an audio source [cd, web, simple function generator], dummy load to save your speakers.

AND KEEP ONE HAND IN YOUR POCKET AT ALL TIMES AROUND LIVE VALVE GEAR!!!



Poor Man's Lab


ACmeasPoint
PS balance can be adjusted with an AC voltmeter measuring between the output of the phase splitter blocking capacitors and the power valve grid input resistor relative to 0vA. 7 volts was the knee where the distortion began to increase rapidly. Typically around 2 or 3 should be fine. With a single voltmeter, start with the pot in the middle [≈5 turns from the click on either end]. Measure each phase and turn the pot to lower the higher voltage phase. Go about half the voltage difference, check the other phase and iterate until they match to 10mV. NOTE: As with all valve gear, it should be well warmed and not just pulled off the shelf after several months. We run an amp for 24 hours @ 10% rated power output in normal service orientation and covers for amps modified or just put in service.

Voltage using the distortion analyzer to achieve 0.01% distortion in the driver board: EZAdjust

Voltage using near maximum voltmeter resolution to achieve 0.022% distortion + noise: EZAdjustLV

As we used to say back in the studio days,

Close enough for Rock & Roll... Way too Close for Jazz!